cobi.wms:datawedge_settings
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| cobi.wms:datawedge_settings [2021/10/29 16:46] – tkammer | cobi.wms:datawedge_settings [2025/08/19 13:23] (current) – [Enable and Configure Intent Output] thuth | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== DataWedge Settings ====== | ====== DataWedge Settings ====== | ||
| + | This guide explains how to configure a Zebra Android scanner so it sends scan data to COBI.wms. | ||
| - | Android-based scanner devices from Zebra need to be configured to make the scanner send scan-data to COBI.wms. This page describes how. | + | ==== Requirements ==== |
| + | * Zebra Android device with DataWedge installed \\ | ||
| + | * COBI.wms | ||
| + | * Tested with DataWedge version 6.7 \\ | ||
| - | ===== Adding a profile ===== | ||
| - | - Open the App "DataWedge" on the Android devices | + | ==== Create a new DataWedge profile ==== |
| - | - Click the three dots at the top right and select | + | 1. Open the DataWedge |
| - | - Name the profile however you like, for example "COBI.wms" | + | 2. Tap the **⋮** menu (top right) and select New Profile. \\ |
| - | - Open the newly created profile to edit it | + | 3. Enter a name, e.g., COBI.wms. \\ |
| + | 4. Open the newly created profile to edit it. \\ | ||
| - | ===== Configuring the profile ===== | + | {{: |
| + | {{: | ||
| - | The following settings have to be changed from the defaults. | + | ==== Link the profile to COBI.wms ==== |
| + | 1. Go to Associated apps. \\ | ||
| + | 2. Tap **⋮** → New app/ | ||
| + | 3. In Select application, | ||
| + | 4. In Select activity, choose | ||
| - | ==== Applications ==== | + | {{: |
| + | {{: | ||
| + | {{: | ||
| + | {{: | ||
| - | The profile has to be associated with the COBI.wms Android app. | ||
| - | - Click on " | + | ==== Configure Barcode Input ==== |
| - | - Click the three dots at the top right and select "New app/activity" | + | You can enable/disable decoders in Decoders. \\ |
| - | - In the " | + | The following setting is required: |
| - | - In the " | + | |
| - | ==== Barcode input ==== | + | 1. Go to Scan params. \\ |
| + | 2. Tap Code Id Type. \\ | ||
| + | 3. Select Code Id Type Aim. \\ | ||
| + | {{: | ||
| + | {{: | ||
| - | In this part of the settings you can change scanning behavior. For example, in the " | + | ==== Disable Keystroke Output ==== |
| + | 1. Open Keystroke output. \\ | ||
| + | 2. Uncheck Enabled. \\ | ||
| - | The following setting is required: | + | {{:playground: |
| - | - Open the menu point "Scan params" | + | {{: |
| - | - Click on "Code Id Type" at the top | + | If Keystroke Output is enabled, COBI.wms may receive duplicated scan data. |
| - | - Select "Code Id Type Aim" | + | |
| - | ==== Keystroke output ==== | + | ---- |
| - | This setting has to be disabled. | + | ==== Enable and Configure Intent Output ==== |
| + | 1. Open Intent output. \\ | ||
| + | 2. Check Enabled. | ||
| + | 3. Tap Intent action → enter: | ||
| + | | ||
| + | 4. Tap Intent delivery → select Broadcast intent. \\ | ||
| - | ==== Intent output ==== | + | {{: |
| - | + | ||
| - | This setting has to be enabled and configured. | + | |
| - | + | ||
| - | | + | |
| - | - Click on the menu point " | + | |
| - | - Enter the following text: '' | + | |
| - | - Click on the menu point " | + | |
| - | - Select " | + | |
| ===== See also ===== | ===== See also ===== | ||
| * https:// | * https:// | ||
| + | |||
cobi.wms/datawedge_settings.1635518807.txt.gz · Last modified: by tkammer